[enterprise] fire fire safety inspection will check the content (report of the Ministry of Public Security No. 120 text)

甘肃安卓工程技术有限公司
Gansu Android Engineering Technology Co., Ltd.
经营范围:安全评价、环境影响评价、环境检测、环境监理;清洁生产审核技术服务;职业卫生健康评估与检测;水土保持方案报告编制、监理、监测;工业设备安装工程、电力工程;工程咨询、设计、监理、验收;应急预案编制、编制重大固定资产社会稳定风险评估报告书;安全文化咨询及培训;消防工程、消防设施检测、维护、保养;消防安全评估;电器设备设施检测、消防电气防火检测、防雷装置检测;地质灾害危险性评估、地质灾害治理工程监理、设计、勘查
Business scope: safety evaluation, environmental impact assessment, environmental monitoring, environmental supervision; cleaner production audit services; occupation health assessment and detection; report preparation, supervising and monitoring of soil and water conservation plan; industrial equipment installation engineering, power engineering; acceptance of engineering consultation, design, supervision, major fixed assets; social stability risk assessment report the preparation of emergency plans, consulting and training; safety culture; fire engineering, fire detection, maintenance, maintenance; fire safety assessment; detection of electrical equipment, electrical fire detection, fire detection of lightning protection devices; prospecting geological hazard assessment, geological disaster control engineering, design, supervision
1单位消防安全管理检查1、消防安全组织机构健全;
1 unit fire safety management inspection 1, fire safety organization sound;
2、消防安全管理制度完善;
2, fire safety management system;
3、日常消防安全管理落实。火灾危险部位有严格的管理措施;定期组织防火检查、巡查,能及时发现和消除火灾隐患;
3, daily fire safety management. Fire risk parts have strict management measures; regular organization of fire inspection, inspection, timely detection and elimination of fire hazards;
4、重点岗位人员经专门培训,持证上岗。员工会报警、会灭初期火灾、会组织人员疏散;
4, the key staff with special training certificates. Staff will alarm, will destroy the initial fire, will organize personnel evacuation;
网络上有太多匿名的丑行,特别是大量不负责任的言论,所以实名对于互联网的健康发展利大于弊,但是要实施它不仅面临复杂的技术和商业问题,更有很多社会问题需要协调解决。
5、对消防设施定期检查、检测、维护保养,并详细完整的记录,可使用iFire消防宝智能点检系统,抄表、记录数据可视化,可疑情况自动分析呈现;
5, regular inspection of fire facilities, inspection, maintenance, and with complete records, you can use the iFire fire Bao intelligent inspection system, meter reading, data visualization, automatic analysis showed suspicious circumstances;
6、灭火和应急疏散预案完备,并有定期演练的记录;
6, fire fighting and emergency evacuation plan is complete, and regular exercise records;
7、单位火警处置及时准确。
7, unit fire disposal timely and accurate.
对设有火灾自动报警系统的场所,随机选择一个探测器吹烟或手动报警,发出报警后,值班员或专(兼)职消防员携带手提式灭火器到现场确认,并及时向消防控制室报告。值班员或专(兼)职消防员会正确使用灭火器消防软管卷盘、室内消火栓等扑救初期火灾。
Automatic alarm system for sites with fire, random selection of a detector or manual blowing smoke alarm, alarm, attendant or special (and) duty firefighters carry portable fire extinguishers to confirm the site, and promptly to the fire control room report. Attendant or special (and) duty firefighters will be the proper use of a fire extinguisher fire hose reel, fire hydrant etc. the initial fire fighting.
2消防控制室检查1、值班员不少于2人,经过培训,持证上岗;
2 check the fire control room attendant 1, not less than 2 people, trained and certified;
2、有每日值班记录,记录完整准确;
2, daily duty records, records complete and accurate;

3、有设备检查记录,记录完整准确;
3, equipment inspection records, records complete and accurate;
4、值班员能熟练掌握《消防控制室管理及应急程序》,能熟练操作消防控制设备;
4, the duty officer can master the fire control room management and emergency procedures, skilled operation of fire control equipment;
5、消防控制设备处于正常运行状态,能正确显示火灾报警信号和消防设施的动作、状态信号,能正确打印有关信息。
5, fire control equipment is in normal operation state, can correctly display the fire alarm signal and the fire equipment, the state signal, can print the relevant information.
3防火分隔检查1、防火分区和防火分隔设施符合要求;
3 fire separation inspection 1, fire compartmentation and fire separation facilities to meet the requirements;
2、防火卷帘下方无障碍物。自动、手动启动防火卷帘,卷帘能下落至地板面,反馈信号正确;
2, under the fire shutter barrier. Automatic, manual start fire shutter, shutter can fall to the floor, feedback signal is correct;
3、管道井、电缆井,以及管道电缆穿越楼板和墙体处的孔洞封堵密实;
3, pipe wells, cable wells, as well as pipeline cable through the floor and wall of the hole sealing;
4、厨房、配电室、锅炉房、柴油发电机房等火灾危险性较大的部位与周围其他场所采取严格的防火分隔,且有严密的火灾防范措施和严格的消防安全管理制度。
4, kitchen, power distribution room, boiler room, diesel generator room etc. greater risk of fire site and other places around the strict fire protection, and strict fire prevention measures and strict fire safety management system.
4人员安全疏散系统检查1、疏散指示标志及应急照明灯的数量、类型、安装高度符合要求,疏散指示标志能在疏散路线上明显看到,并明确指向安全出口;
4 safety evacuation system check 1, emergency evacuation signs and emergency lighting quantity, type, installation height to meet the requirements, evacuation signs can be seen in the evacuation route, and clearly point to the exit;
2、应急照明灯主、备电源切换功能正常,切断主电后,应急照明灯能正常发光;
2, emergency lighting main, standby power switching function is normal, cut off the main power, emergency lighting can be normal light;

昆山市两人获评省优秀首席信息官

3、火灾应急广播能正常播放,正确引导人员疏散;
3, fire emergency broadcast can play, the correct guidance of the evacuation;
4、封闭楼梯、防烟楼梯及其前室的防火门向疏散方向开启,具有自闭功能,并处于常闭状态;平时因频繁使用需要常开的防火门能自动、手动关闭;平时需要控制人员随意出入的疏散门,不用任何工具能从内部开启并有明显标识和使用提示;常开防火门的启闭状态在消防控制室能正确显示;
The fire door closed, 4 stairs, smoke proof staircase and vestibule opening to the evacuation direction, has the function of self closing, and in a normally closed state; usually due to frequent use to open fire doors can automatically and manually shut down; usually need to control the personnel evacuation door freely, without any tools can open from the inside and has the obvious the identification and use tips; normally open fire doors open and close state in the fire control room can display correctly;
5、安全出口、疏散通道、楼梯间保持畅通,未锁闭,无任何物品堆放。
5, safety exits, evacuation routes, staircases remain open, not locked, without any items stacked.
5火灾自动报警系统检查1、检查故障报警功能。摘掉一个探测器控制设备能正确显示故障报警信号;
5 automatic fire alarm system check 1, check the fault alarm function. Remove a detector control device can correctly display fault alarm signal;
2、检查火灾报警功能。任选一个探测器进行吹烟,控制设备能正确显示火灾报警信号;
2, check the fire alarm function. A detector can be used for blowing smoke, and the control device can display the fire alarm signal correctly;
3、检查火警优先功能。摘掉一个探测器,同时给另一个探测器吹烟,控制设备优先显示火灾报警信号。
3, check the fire alarm priority function. Remove a detector, at the same time to another detector blowing smoke, fire alarm signal priority control equipment display.
6湿式自动喷水灭火系统检查1、报警阀组件完整,报警阀前后的阀门、通向延时器的阀门处于开启状态;
6 wet automatic sprinkler system check 1, alarm valve components complete, the alarm valve before and after the valve, the valve is turned on to the delay state;
2、对自动喷水灭火系统进行末端试水。将消防控制室联动设备设置在自动位置,任选一楼层,控制设备能正确显示水流报警信号;压力开关动作,水力警铃发出警报,喷淋泵启动,控制设备能正确显示压力开关动作及启泵信号。
2, the sprinkler system to test the end of the water. The fire control room linkage device is arranged in the automatic position, optionally a floor control device can correctly display the current alarm signal; the pressure switch, water alarm alarm, spray pump start control device can correctly display the pressure switch and start the pump signal.
7消火栓、水泵接合器检查1、室内消火栓箱内的水枪、水带等配件齐全,水带与接口绑扎牢固;
7, check 1 fire hydrant pump adapter, indoor hydrant box, water hose and hose and accessories complete, firm binding interface;
2、检查消火栓功能。任选一个室内消火栓接好水带、水枪,看水枪出水是否正常;
2, check the function of the fire hydrant. Choose a fire hydrant hose connected, water gun, water gun water to see whether it is normal;
3、室外消火栓不被埋压、圈占、遮挡。标识明显,有专用开启工具,阀门开启灵活方便,出水正常;
3, outdoor fire hydrant and occupy, not buried shelter. Identification is obvious, there are special opening tool, the valve is open and flexible and convenient, normal water;

对话OneASP何迪生:回归安全之路,从0到1

4、水泵接合器不被埋压、圈占、遮挡。标识明显,并标明供水系统的类型及供水范围。
4, pump adapter not buried, occupy or cover. Identification is obvious, and the type of water supply system and water supply scope.
8防烟排烟系统检查1、检查加压送风系统。自动、手动启动加压送风系统,相关送风口开启,送风机启动,送风正常,反馈信号正确。
8 smoke prevention and exhaust system check 1 check the pressurized air supply system. Automatically and manually start the pressurization air supply system, the relevant air supply opening, the blower start, the air supply is normal, the feedback signal is correct.

想成为 IT审计师吗 c-author

2、检查排烟系统。自动、手动启动排烟系统,相关排烟口开启,排烟风机启动排风正常,反馈信号正确。
2, check smoke exhaust system. Automatically and manually start the smoke exhaust system, the relevant exhaust port is opened, the exhaust fan starts the exhaust air is normal, the feedback signal is correct.
9灭火器检查1、灭火器配置类型正确,如有固体可燃物的场所配有能扑灭A类火灾的灭火器;
9 fire extinguisher inspection 1, the fire extinguisher disposition type is correct, if has the solid combustible place to have to be able to extinguish the class a fire extinguisher;
2、储压式灭火器压力符合要求,压力表指针在绿区;
2, storage type fire extinguisher pressure to meet the requirements, the pressure gauge pointer in the green zone;
3、灭火器设置在明显和便于取用的地点,不影响安全疏散;
3, the fire extinguisher is set in a clear and easy to take place, does not affect the safety evacuation;
4、灭火器有定期维护检查的记录。
智能穿戴设备的安全议题探讨及建议
4, fire extinguishers have regular maintenance inspection records.
10给水和储水设施检查1、配电柜上控制消火栓泵、喷淋泵、稳压泵的开关设置在自动(接通)位置;
10 water supply and water storage facilities, distribution cabinet control check 1 fire hydrant pump, spray pump, pump switch is arranged in the automatic position (on);
2、消火栓泵和喷淋泵进、出水管阀门,高位消防水箱出水管上的阀门,以及自动喷水灭火系统、消火栓系统管道上的阀门保持常开;
2, fire pump and spray pump inlet and outlet valves, fire water tank outlet pipe on the valve, and the automatic sprinkler system, fire hydrant system piping valve stays open;
3、高位消防水箱、消防水池、气压水罐等消防储水设施的水量达到规定的水位;
3, the high fire water tank, fire water tank, pressure tank, fire water storage facilities of water to reach the required level;
4、北方寒冷地区的高位消防水箱和室内外消防管道有防冻措施。
4, the northern cold areas of high fire tank and indoor and outdoor fire fighting pipe antifreeze measures.
11室内装修检查1、疏散楼梯间及前室和安全出口的门厅其顶棚、墙面和地面采用不燃材料装修;
The 11 interior decoration check 1, evacuation staircase and antechamber and exit the ceiling, wall and floor decoration with incombustible materials;
2、房间、走道的顶棚、墙面、地面使用符合规范规定的装修材料;
2, room, aisle ceiling, wall and floor decoration materials used comply with the specifications;
3、疏散走道两侧和安全出口附近无误导人员安全疏散的反光镜子、玻璃等装修材料。
3, on both sides of the evacuation corridor and near the exit of the security personnel without the safe evacuation of reflective mirrors, glass and other decoration materials.
12外墙保温材料和装修检查1、了解掌握建筑外箱和屋顶保温系统构造和材料使用情况;
12 external wall insulation materials and decoration inspection 1, understand the construction of the outer box and roof insulation system structure and material usage;
2、了解外墙和屋顶使用易燃可燃保温材料的建筑,其楼板与外保温系统之间的防火分隔或封堵情况,以及外墙和屋顶最外保护层材料的燃烧性能;
2, to understand the use of external walls and roofs of flammable combustible insulation materials of the building, the floor and the external insulation system between the fire separation or plugging, as well as the outer wall and roof of the most protective layer of the material combustion performance;
3、对外墙和屋顶使用易燃可燃保温、防水材料的建筑,有严格的动火管理制度和严密的火灾防范措施。
3, on the roof and walls of the use of flammable and combustible insulation, waterproofing materials, construction, strict management system and strict fire fire prevention measures.
13其他检查1、备电供电和自动切换正常。切换主、备电源,检查其供电功能,设备运行正常;
13 other inspection 1, power supply and automatic switching normal. Switch the main and standby power supply, check the power supply function, the equipment is running normally;